Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
Acta Pharmaceutica Sinica ; (12): 229-235, 2017.
Article in Chinese | WPRIM | ID: wpr-779583

ABSTRACT

Postoperative intra-abdominal adhesion is one of the most common complications in the postoperative period. Current remedies are very ineffective to prevent the pathological outcomes except steroid hormones. Rhynchophylline is deemed as a pharmacologically active component from traditional Oriental medicine Uncaria rhynchophylla (Miq.) Jacks. (Rubiaceae). This study was designed to investigate the preventative effect of rhynchophylline on the abdominal adhesions in rats. Rhynchophylline relieved the experimental abdominal adhesion and decreased the levels of interleukin-1β (IL-1β), interleukin-6 (IL-6) and tumor necrosis factor-α (TNF-α) in the blood serum in a dose-dependent manner. The levels of transforming growth factor-β1 (TGF-β1) and connective tissue growth factor (CTGF) were reduced significantly in the peritoneal fluid. The potential mechanism of the activity is related to inhibition of the TGF-β1/Smad signaling pathway.

2.
Chinese Journal of Laboratory Medicine ; (12)2003.
Article in Chinese | WPRIM | ID: wpr-685496

ABSTRACT

Objective To evaluate the performance of the ABX Micro C-reactive protein(CRP)in determination of CRP.Methods The analytic characteristics including precision,carry-over,linearity, stability,interference and comparability were examined.Results The coefficient of variation(CV)was less than 5.1%,10% and d.3% for within-run,between-run and between-day,respectively.Carryover was less than 1.2%.Whole blood samples held at either room temperature or 4℃ were stable for 48 hours with relative deviation less than 6.0% relatively.Linear range was 1.0-70.0 mg/L using undiluted samples.The comparison between the ABX Micro CRP and Behring Nephelometer Ⅱ was well correlated Both serum:Y=0.996 7X-0.398 5,r~2=0.965 9;serum for BN Ⅱ,whole-blood samples for the ABX Micro CRP:Y=0.908 8X-0.138 2,r~2=0.959 4;both serum and whole-blood samples for the ABX Micro CRP: Y=1.001 7X-0.898 2,r~2=0.952 7.No obvious interference was observed by hyperhemoglobinemia and hyperlipidemia.Conclusion The determination of CRP test with ABX Micro is accurate and reliable.

3.
Chinese Journal of Laboratory Medicine ; (12)2001.
Article in Chinese | WPRIM | ID: wpr-685372

ABSTRACT

The paper introduces the development of hematology analysis technique in recent 10 years,and mainly concentrates in WBC differential technique,the extended functions and automation.The clinical application of red cell volume distribution width,reticulated platelets and reticulocyte subpopulation are also described in the paper.The common problems in the usage of hematology analyzer and correction methods are pointed out.

SELECTION OF CITATIONS
SEARCH DETAIL